BESPOKE DUCTWORK

 

2JCP were asked to provide bespoke ductwork to be installed for a gas pipeline company with a compressor station in NE USA. This ductwork would be added to two Solar gas turbines. One a Solar Taurus 70 and the other a Solar Centaur 40. The goal was to increase gas compression capacity during the warm summers and cold winters in the NE. A design which could provide a dual solution for summer cooling and winterization was to be created. We collaborated with our customer to design ductwork between the gas turbine compressor and the cooling system with doors which, when shut, acted as an automatic cut off to the cooling system when temperatures dropped without affecting turbine operations.

 

Project Type: Build to Specification

Location: NE USA

Gas Turbine Type: Solar Taurus 70 & Solar Centaur 40

Finished in: 2014